What a Septic Inspection Covers
On a lot with its own well, the inspection starts by recording the water supply. Under Rule .1006, the inspector notes the type of water supply, such as a well or public water, and the septic tank's distance from the well, the house and any visible water line.
The tank gets a close look. The same rule lists the depth to the top of the tank or riser, the presence of risers, the condition of the lids, baffle wall and outlet tee, the water level relative to the outlet, any outlet filter, roots, leakage, non-permitted connections from downspouts or sump pumps, the date of the last pumping if known, and the percentage of solids.
The field follows: its type, the number and length of lines, signs of past or current surfacing, traffic over it, vegetation, grading and drainage as they affect the system, and confirmation that effluent is reaching it.
Behind those details is Rule .1005, which requires the inspector to inspect and describe the septic tank, pump tanks, distribution devices, dispersal fields, treatment units and control panels, uncover lids and distribution devices unless blocked, and probe where deterioration is suspected. Rule .1002 frames the visit with a signed contract and the owner's written permission beforehand, and a written report within 10 business days that names anything not inspected and why.